NOTE
These instructions assume that you have just DETACHED from an attachment and the LOCK-OUT switch is ON.
Engage the FRONT PIN of the attachment. The tenX Safety Knuckle will be instantly locked to the pin.
Lower the coupler to the REAR PIN.
Before lifting the attachment, ensure that the coupler is aligned so that the C-CAVITY takes the attachment weight, not the Safety Knuckle.
Lift the attachment off the ground. It may swing a little depending on the centre-of-gravity.
Crowd the coupler so that the attachment pins are NEAR VERTICAL. This will press the REAR PIN hard against the coupler chassis.
Turn the LOCK-OUT switch OFF. With the coupler crowded, this will extend the Primary Wedge to engage the REAR PIN.
* SEE NOTE BELOW
Shake the attachment to ensure a correct engagement.
NOTE
These instructions assume that an attachment has just been detached and the LOCK-OUT switch is already ON.
If attaching for the first time or if the tenX coupler was empty, at STEP 6, turn the LOCK-OUT switch ON with the coupler crowded. This will RETRACT the Primary Wedge if it was extended. Wait a moment, then switch the LOCK-OUT switch OFF to extend the Primary Wedge and engage the REAR PIN.
If the REAR PIN was resting against an extended Primary Wedge, you will see the attachment settle against the coupler chassis.